Integrating GroundProbe SSR
Viewer Alarms with PageGate
Send Text and SMS Messages from GroundProbe
Follow these steps to use GroundProbe SSR Viewer
Alarms with PageGate.
The GroundProbe system generates .csv format
files that PageGate then finds and processes into
a SMS this is then sent out to the client via
a fitted USB dial up modem fitted with a local
SIM card.
GroundProbe CAD uses PageGate's
GetAscii module to pass messages to PageGate for
delivery. To configure PageGate to accept the
messages from the CAD:
1) In Windows, create the
following directory: C:\PageGateData\Ascii\
2) Open the PageGate Admin.
3) Go to Interfaces - GetAscii
- Settings.
4) Set the Polling Directory
to: c:\PageGateData\Ascii\
5) Put a check in Enabled.
6) Click on Apply.
7) Click on Yes.
8) Go to Interfaces - GetAscii
- Settings - Advanced Polling - Files.
9) Click on Add.
10) Specify the following:
Recipient: *
From: Enter a Sender's Name here
File(s): *.csv
Path: Enter the Path to which GroundProbe is outputting
its data. By default, this directory is c:\ssr\SMS\
but may be different for your installation of
GroundProbe.
File Type: Adding
11) Click on Apply.
12) Go to Interfaces - GetAscii
- Settings - Advanced Polling - Record
13) Specify the following:
Start Pattern: *
Start Offset: 0
End Pattern: \013\010
End Offset: 0
14) Click on Apply.
15) Go to Interfaces - GetAscii
- Settings - Advanced Polling - Recipient
16) Specify the following:
Start Pattern: *
Start Offset: 0
End Pattern: -
End Offset: 0
17) Click on Apply.
18) Go to Interfaces - GetAscii
- Settings - Advanced Polling - Sender
19) Select 'Static Sender'
20) Enter a Sender's Name
in the Sender field.
21) Click on Apply.
22) Go to Interfaces - GetAscii
- Settings - Advanced Polling - Message
23) Specify the following:
Start Pattern: *
Start Offset: 0
End Pattern: ~
End Offset: 0
24) Click on Apply.
|