Integrating OneSolution CAD with PageGate
Send Text and SMS Messages from OneSolution CAD
How to Integrate
With OneSolution CAD ability to execute an external
program, you can send a message to a pager or
cell phone using PageGate.
PageGate Settings
GetAscii (Commandline/Ascii) Settings
PageGate's GetAscii (Commandline/Ascii) interface
must be enabled for the integration of PageGate
and WebWatchBot.
1. Run PageGate's Administration program
(PG Admin)
2. Double-click on the 'Interfaces' object.
3. Double-click on the 'GetAscii' object.
4. Click on the 'Settings' object.
5. Type in a path for PageGate to use as
a polling directory for this interface (or hit
the '...' button to browse to an existing folder).
6. Check the 'Enabled' checkbox.
7. Click the 'Apply' button. Recipient/Group
Settings
PageGate recipients and groups
must have the Ascii service enabled in order to
receive messages from OneSolution CAD
1. Add a new or edit an existing PageGate
recipient or group.
2. On the recipient's or group's settings
screen, check the 'Ascii' checkbox in the 'Enabled
Services' section.
3. Click the 'Apply' button. GUI Client
Settings
|